News information
|
Application of Diverter in Floor Heating1. First run hot water supply: The first operation should gradually inject hot water - when starting the underfloor heating for the first time, first open the main water supply loop valve of the water collector to gradually increase the temperature of the hot water and inject it into the pipeline for circulation. Check if there are any abnormalities in the interface of the water collector, and gradually open the valves of each branch of the water collector. If there is leakage in the water collector and pipeline, the main water supply valve should be closed in a timely manner and the developer or underfloor heating company should be contacted in a timely manner. 2. First time exhaust method: During the first operation of underfloor heating, due to pressure in the pipeline and water resistance, it is easy to cause air blockage, resulting in non circulation of water supply/return and unequal temperature. At this time, exhaust should be carried out step by step. The method is to close the main return water valve of the heating system and adjust each loop. First, open one of the regulating valves on the water collector, then open another regulating valve on the water collector, and then open the exhaust valve on the return water bar of the water collector to discharge water and exhaust air. After exhausting the air, close this valve and open the next valve. Repeat this process until all the air in each loop is completely discharged before opening the valve, and the system will officially start running. 3. If the outlet pipe is not hot, the filter should be cleaned: Each water collector is equipped with a filter in front of it. When there are too many impurities in the water, the filter should be cleaned in a timely manner. When there are too many impurities in the filter, there may be phenomena such as the outlet pipe not being hot and the floor heating not being hot. Usually, the filter should be cleaned once a year. 4. Methods for cleaning filters: Close all valves on the water separator, use an adjustable wrench to open the filter end cover counterclockwise, remove the filter for cleaning, and install it back in its original state after cleaning. Open the valve, and the underfloor heating system can work normally. If there is no heating in winter and the indoor temperature is below 1 ℃, it is recommended that users drain the water in the underfloor heating coil to prevent the pipeline from freezing and cracking.
|